Specifications:
|
Applicable
fibres |
SM
(ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655) and
other SMF including ITU-T G.657 fibres |
|
Fibre
Count |
Single |
|
Cladding
diameter |
80
to 150um |
|
Coating
diameter |
100
to 1000um |
|
Fibre
cleaved length |
8mm
to 16mm using Sheath Clamp A, B or C/ 10mm using FH-60-250, FH-60-900 |
|
Actual
average splice loss |
0.02dB with SM, 0.01dB with MM, 0.04dB
with DS, 0.04dB with NZDS. Measured by cut-back method relevant to ITU-T
standards. |
|
Splice
time |
Typical
9sec. with standard SM fibre. |
|
Return
loss |
60dB
or greater |
|
Splicing
modes |
Total
number available equals 100; for pre-set modes and user programmable modes |
|
Splice
loss estimate |
Several
types of core deformations as well as core axis offset are taken into
account for accurate loss estimate. |
|
Attenuation
splice function |
Intentional
high splice loss of 0.1dB to 15dB (0.01dB step) can be made for an inline
fixed attenuator |
|
Storage
of splice result |
The
last 2000 results to be stored in the internal memory. |
|
Fibre
display |
X/Y,
or both X and Y simultaneously |
|
Magnification |
300x
for single X or Y view, or 187x for X and Y view. |
|
Viewing
method |
By
two CMOS cameras for fibre viewing and 4.1inches TFT colour LCD monitor |
|
Image
change over |
The
fibre image is turned upside down automatically according to the monitor
position. |
|
Operating
condition |
0-5000m
above sea level, 0-95% RH and -10 to 50C
respectively. |
|
Mechanical
proof test |
2N
(standard) |
|
Tube
heater |
Built-in
auto-start tube heater with 10 heating modes and up to 20 for reference |
|
Tube heat
time |
Typical
30sec.with FP-03 protection sleeve. |
|
Applicable
protection sleeve length |
60mm,
40mm and a series of micro sleeves. |
|
No. of
splice/heating with battery |
160
cycles with BTR-08. |
|
Power
supply |
Auto
voltage selection from 100 to 240Va.c. or 10 to 15Vd.c. with ADC-13.
13.2Vd.c. with BTR-08 |
|
Terminals |
USB1.1
(USB-Mini B) for data and video signal transfer to PC. |
|
Wind
protection |
Max.
wind velocity of 15m/s. |
|
Dimensions |
136(W)
x 161(D) x 143(H) mm |
|
Weight |
2.3kg,
with ADC-13 AC Adaptor, 2.7kg, with BTR-08 Battery |
Standard package:

|
Description |
Model No. |
Q'ty |
Note |
|
Arc
Fusion Splicer |
FSM-60S |
1pc. |
-- |
|
Sheath
Clamp |
CLAMP-S60A |
1pc. |
Installed |
|
Electrodes |
ELCT2-20A |
1
pair |
Installed |
|
Wind
Protector Mirror |
WPM-08 |
2pc. |
Installed,
replaceable by user |
|
AC
Adaptor/Battery Charger |
ADC-13 |
1pc. |
-- |
|
AC Power
Cord |
ACC-xx |
1pc. |
ACC-16
UK Type |
|
Spare
Electrodes |
ELCT2-20A |
1
pair |
-- |
|
USB Cable |
USB-01 |
1pc. |
-- |
|
Quick
Reference Guide |
M-60S/18S-E |
1pc. |
English |
|
Video
Instruction Manual |
V-60S-E |
1pc. |
CD,
English |
|
Warning
& Cautions |
W-60-E |
1pc. |
English |
|
Splicing
Report |
- |
1pc. |
English |
|
J-Plate |
JP-05 |
1pc. |
-- |
|
Carrying
Case |
CC-24-60S |
1pc. |
-- |
Optional items:
|
Description |
Model No. |
Note |
|
Fibre
Holder |
FH-60-250 |
For
250um coating |
|
FH-60-900 |
For
900um coating |
|
|
Sheath
Clamp |
CLAMP-S60A |
For
coating diameter up to 250um, 8mm to 16mm cleave |
|
For
coating diameter of over 250um, 16mm cleave |
||
|
CLAMP-S60B |
For
coating diameter up to 1000um, 8mm to 16mm cleave |
|
|
CLAMP-S60C |
For
900um loose tube fibre |
|
|
Battery
Pack |
BTR-08 |
-- |
|
Battery
Charge Cord |
DCC-14 |
Use
for connecting BTR-08 and ADC-13 |
|
DC
Power Cord |
DCC-12 |
For
ADC-13, cigarette lighter socket type |
|
DCC-13 |
For
ADC-13, alligator clamp type |
|
|
Magnifier |
MGS-06 |
With
bracket |
|
Electrodes |
ELCT2-20A |
-- |
|
Wind
Protector Mirror |
WPM-08 |
-- |
|
High
Precision Fiber Cleaver |
CT-30 |
-- |
To see the technical specifications in PDF format, please consult the following document:
fibre_splicers_FSM-60Sdatasheet.pdf (118 KB)
Related information about the same topic:
- FSM 60S General presentation