Caracteristici avansate:
Performante Ultra-Fine dedicate pentru identificarea fibrelor Bend-Insensitive
Capacitatea de a detecta semnale de ton slab peste semnal de trafic puternic
Power metru optic integrat in FID-25R (Max. +10dBm)
15 moduri de testare selectabile de utilizator pentru diverse aplicatii
Modul complet de testare executa toate testele de identificare in acelasi timp intr-o singura operatie de inclestare
Capat de cleste avansat ce permite identificarea tuturor fibrelor fara schimbare
Cap de inclestare superior conceput astfel incat sa necesite o suprafara foarte mica de fibra pentru a face testarea.
Caracteristici de design:
Acces usor la fibra chiar si in zone inguste datorita constructiei lungi si subtiri
Operatiune simpla si automata, trebuie doar sa inclestati fibra
Ecran LCD si LED-uri pentru citirea usoara a rezultatelor indicate
Functie de indicare a directiei semnalului si a fibrei cu semnal
Capabilitate excelenta de identificare sub actiunea razelor solare
Dispozitiv de protectie impotriva razelor solare pentru facilitarea identificarii in astfel de conditii.
Specificatii Tehnice:
| Model | FID-25R: Identificator fibra optica cu functie de masurare a puterii FID-26R: Identificator fibra optica |
|
| Applicable fibers | Fiber type | Singlemode fiber |
| Kind of fiber | 0.25mm
coating, Ribbon fiber up to 12-fiber, or Fiber cord : 1.1mm, 1.5mm, 1.7mm, 2.0mm, or 3.0mm |
|
| Optical characteristics |
Wavelenght range | 900 to 1700nm |
| Detectable light signals | Traffic signal, CW light, Light signal with modulated tones at 270Hz, 1kHz or 2kHz (square wave 50±10% duty cycle) | |
| Test modes | Total
15 modes, combination of detectable light signals and number of signal sellect (1-signal to 4-signal) |
|
| Operating conditions | -10 to +50°C , 0 to 95% RH | |
| Storage conditions | -20 to +60°C , 0 to 95% RH | |
| Power supply | 1.2 to 1.5V DC with two AA batteries 100 to 240V AC with optional FID-AA2 | |
| Battery Life | Aapproximately 8 Hours by alkaline batteries at room temperature | |
| Dimensions and weight | 40W x 190D x 26H (mm), 180g including battery | |
| Power meter | Wavelength response | 1310nm, 1550nm |
| Detectable kind of signal | Traffic signal, CW light, Light signal with modulated tones at 270Hz, 1kHz or 2kHz (square wave 50±10% duty cycle) | |
| Detector Sensitivity | +10
to -60dBm at modulated tone +10 to -40dBm at traffic signal & CW light |
|
| Accuracy | Within +/-0.3dB at room temperature | |
Apasati aici pentru a vedea specificatiile
Pachetul standard contine:
| Optical fiber identifier | Plunger | Light shield rubber | Carrying case | Instruction manual | Connector head |
| FID-25R | PL-05 | LSR-02 | FID-CASE-01 | English | OCH-01-UC (Universal type) |
| FID-26R | PL-05 | LSR-02 | FID-CASE-01 | English | - |
Optionale:
| Description | Model No. | Use for |
| Connector head | OCH-01-SC | FID-25R, SC connector |
| OCH-01-FC | FID-25R, FC connector | |
| OCH-01-ST | FID-25R, ST connector | |
| AC adaptor | FID-AA2 | FID-25R and FID-26R |
| AC power cord | ACC-08 ~ 12 | FID-AA2 |
Informatii aditionale pe site: