Modelul Noyes OFL280 produs de AFL Telecommunications este un OTDR (Optical Time Domain Reflectometer) pentru fibre single mode si vine in doua variante optimizate FTTx. Modelul pentru instalare si reparare poate opera la trei lungimi de unda (1310/1550/1625 nm) pe fibre fara semnal, dar se schimba automat intr-un mod filtrat pe 1625nm in momentul detectarii semnalului pe fibra. In plus, portul de test este echipat cu un PON power meter care permite detectarea de fibre FTTx cu semnal, masurarea nivelurilor de putere ale retelelor FTTx si localizarea problemelor pe retelele FTTx cu un singur OTDR conectat la retea si un singur test automat. Este disponibil si un model conventional cu trei lungimi de unda (1310/1550/1625 nm) care permite localizarea defectelor aparute pe retele fara semnal.

Cerere oferta & informatii OFL280

Ambele modele OFL280 pot functiona in mod Full Auto, Timp Real sau in modul Expert (manual) si ofera: analiza precisa a evenimentelor, optical power meter, sursa laser, durata de viata a bateriei de 12 ore, spatiu intern de stocare si conectivitate USB. Porturile OTDR si OPM sunt echipate cu adaptoare care nu necesita alte unelte pentru schimbare.

Rezultatele sunt salvate in format .SOR si pot fi transferate pe un PC pentru vizualizare, tiparire si analizare cu software-ul livrat in pachet, compatibil Windows.

Aplicatii:
• Testarea fibrelor fara semnal pentru trei lungimi de unda
• Testarea fibrelor cu semnal la 1625 nm
• Masurarea sudurilor, a conexiunilor si a pierderilor de la un capat la celalalt
• Masurarea reflectantei conectorilor
• Masurarea nivelurilor de putere pentru retele FTTX la 1490 si la 1550 nm
• Testare terminalelor si a patch panelurilor cu ajutorul VFL (visual fault locator)
• Localizarea indoirilor fibrei
• Capacitatea de urmarire a fibrelor de pana la 5 km cu ajutorul VFL
• Masurarea pierderii de la un capat la celalalt cu ajutorul OLS si OPM.

Caracteristici:
check icon Poate fi tinut in mana, 0.8 kg (1.7 lb)
check icon 1.3 m event dead zone
check icon 30 dB (28 dB @ 1625 nm) dynamic range
check icon FTTx construction model (OFL280-102) include:
       - 1310/1490/1550 nm
check icon FTTx installation model (OFL280-103) include:
       - 1310/1550/1625 nm
       - PON power meter
       - Live fiber filter at 1625 nm
check icon OPM, OLS, si VFL (650 nm)
check icon Memorie interna (> 1,000 fisiere cu teste)
check icon Ecran LCD de 3.5 inch
check icon Baterie reincarcabila Li-Ion cu durata de 12 ore
check icon Conexiune USB cu PC.

Specificatii Tehnice:

OTDR
Emitter Type Laser
Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Fiber Type Single-mode
Available Wavelengths 1310/1490/1550/1625 nm
Wavelength Tolerance ±20/±20/±20/±10 nm
Dynamic Range (SNR=1) 30/30/30/28 dB
Event Dead Zone 1 1.3 m
Attenuation Dead Zone @ 5ns 2 Typical 5.0 m, maximum 6.0 m
Pulse Widths 5, 10, 30, 100, 300 ns, 1, 3, 10 us
Range Settings 250 m to 256 km
Data Points Up to 16,000
Data Point Spacing 12.5 cm (range <4 km), Range/16000 (range > 4 km)
Group Index of Refraction (GIR) 1.4000 to 1.6000
Distance Uncertainty (m) ± (1 + 0.005% x distance + data point spacing)
Trace File Format Bellcore GR-196 V.1.1
Trace File Storage Medium Internal memory (>1000 traces)
Data Transfer to PC USB cable
OTDR Modes Full Auto, End Locate, Expert, Live
1. Typical distance between the two points 1.5 dB down each side of a reflective spike caused by a -45 dB event using 10 ns pulse width.
2. Typical distance from event location to point where trace is within 0.5 dB of backscatter.

 

PON POWER METER
Calibrated Wavelengths 1490, 1550 nm
Detector Type InGaAs
Isolation > 40 dB
Measurement Range +23 to - 50 dBm
Accuracy 1 ± 0.5 dB
Resolution 0.01 dB
Measurement Units dBm or watts
OPTICAL POWER METER
Calibrated Wavelengths 1310, 1490, 1550, 1625, 1650 nm
Detector Type InGaAs
Measurement Range +23 to - 50 dBm
Tone Detect Range +3 to -35 dBm
Wavelength ID Range +3 to -35 dBm
Accuracy 1 ± 0.25 dB
Resolution 0.01 dB
Measurement Units dBm or watts
1. At calibration wavelengths, and power level of approximately-10 dBm.

 

LASER SOURCE
Emitter type Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Fiber type Single-mode
Available Wavelengths (nm) 1310/1490/1550 or 1310//1550/1625
Wavelength Tolerance ± 20, ± 10 nm @ 1625 nm
Spectral Width (FWHM) 5 nm (maximum)
Internal Modulation 1 kHz, 2 kHz, CW
Wavelength ID (one, two, or three wavelengths) Compatible with Noyes Optical Power Meters and Light Sources
Output Power Stability < ± 0.25 dB after 15 min
Output Power - 3 dBm

 

VISUAL FAULT LOCATOR
Emitter Type Laser
Safety Class Class II FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Wavelength 650 nm
Output Power (nominal) 0.8 mW into SMF-28

 

GENERAL
Size (in boot) 19 x 11.2 x 4.7 cm (7.5 x 4.4 x 1.9 in)
Weight 0.8 kg (1.7 lb)
Operational Temperature -10 to +50°C, 0 to 95% RH (non-condensing)
Storage Temperature -20 to +60°C, 0 to 95% RH (non-condensing)
Power Rechargeable Li-Ion or AC adapter
Battery Life

(backlight ON in OTDR mode)

12 hours
Display LCD, 320 x 240, 3.5 inch (89 mm), color, transflective
OTDR and OPM Ports Switchable, see web site or contact AFL for available adapter types

 

Aceste detalii tehnice le puteti vedea si in format PDF, accesand documentul urmator (in limba engleza):