Noyes OFL280 Handheld FTTx Single-mode OTDR

Noyes OFL280 FTTx

NEW: This model was replaced by OFL280 FlexTester

The Noyes OFL 280 from AFL Telecommunications is a single-mode OTDR (Optical Time Domain Reflectometer) offered in two FTTx-optimized models. The 'installation and repair' model can operate at three wavelengths (1310/1550/1625 nm) on dark fibers but automatically switches to a filtered, 1625 nm only mode if a live fiber is detected. In addition, the test port is equipped with a PON power meter, which allows the OFL280 to detect live FTTx fibers, measure FTTx network power levels, and fault-locate live FTTx fibers with a single OTDR to network connection and a single automated test. A conventional three-wavelength (1310/1490/1550 nm) 'construction' model is also available to certify or fault-locate dark fibers in FTTx or other networks.

Request an Offer & Information OFL280

Both OFL280 models can operate in Full Auto, Real-Time, or Expert (manual) modes, and offer precision event analysis, an optical power meter, laser source, 12-hour battery life, internal data storage, and USB connectivity. OTDR and OPM test ports are equipped with tool-free adapters, which can be changed in seconds.

Results are saved as industry standard .SOR files, which can be transferred to a PC for viewing, printing, and analyzing with supplied Windows® compatible software.

Applications:
• Test dark fibers at up to three wavelengths
• Test live FTTx fibers at 1625 nm
• Measure splice, connection, and end-to-end loss
• Measure connection reflectance
• Measure FTTx downstream power levels at 1490 and 1550 nm
• Troubleshoot splice trays, terminals, and patch panels using the VFL
• Locate fiber 'macro' bends
• Trace fibers up to 5 km using the VFL
• Measure end-to-end loss using the OLS and OPM.

Features:
check icon Handheld, 0.8 kg (1.7 lb)
check icon 1.3 m event dead zone
check icon 30 dB (28 dB @ 1625 nm) dynamic range
check icon FTTx construction model (OFL280-102) includes:
       - 1310/1490/1550 nm
check icon FTTx installation model (OFL280-103) includes:
       - 1310/1550/1625 nm
       - PON power meter
       - Live fiber filter at 1625 nm
check icon OPM, OLS, and VFL (650 nm)
check icon Internal memory (> 1,000 trace files)
check icon 3.5-inch, indoor/outdoor LCD display
check icon 12-hour, rechargeable Li-Ion battery
check icon USB port for PC connection

All OFL280 models come with a carry case, (1) SC adapter for the OTDR/OLS port, (1) 2.5 mm Universal adapter for the OPM port, (1) 2.5 mm Universal adapter for the VFL port, USB cable (connects with normal (Type A) USB port on your PC), AC power adapter with a country specific power cord, and a user guide.

Specifications:

OTDR
Emitter Type Laser
Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Fiber Type Single-mode
Available Wavelengths 1310/1490/1550/1625 nm
Wavelength Tolerance ±20/±20/±20/±10 nm
Dynamic Range (SNR=1) 30/30/30/28 dB
Event Dead Zone 1 1.3 m
Attenuation Dead Zone @ 5ns 2 Typical 5.0 m, maximum 6.0 m
Pulse Widths 5, 10, 30, 100, 300 ns, 1, 3, 10 us
Range Settings 250 m to 256 km
Data Points Up to 16,000
Data Point Spacing 12.5 cm (range <4 km), Range/16000 (range > 4 km)
Group Index of Refraction (GIR) 1.4000 to 1.6000
Distance Uncertainty (m) ± (1 + 0.005% x distance + data point spacing)
Trace File Format Bellcore GR-196 V.1.1
Trace File Storage Medium Internal memory (>1000 traces)
Data Transfer to PC USB cable
OTDR Modes Full Auto, End Locate, Expert, Live
1. Typical distance between the two points 1.5 dB down each side of a reflective spike caused by a -45 dB event using 10 ns pulse width.
2. Typical distance from event location to point where trace is within 0.5 dB of backscatter.

 

PON POWER METER
Calibrated Wavelengths 1490, 1550 nm
Detector Type InGaAs
Isolation > 40 dB
Measurement Range +23 to - 50 dBm
Accuracy 1 ± 0.5 dB
Resolution 0.01 dB
Measurement Units dBm or watts
OPTICAL POWER METER
Calibrated Wavelengths 1310, 1490, 1550, 1625, 1650 nm
Detector Type InGaAs
Measurement Range +23 to - 50 dBm
Tone Detect Range +3 to -35 dBm
Wavelength ID Range +3 to -35 dBm
Accuracy 1 ± 0.25 dB
Resolution 0.01 dB
Measurement Units dBm or watts
1. At calibration wavelengths, and power level of approximately-10 dBm.

 

LASER SOURCE
Emitter type Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Fiber type Single-mode
Available Wavelengths (nm) 1310/1490/1550 or 1310//1550/1625
Wavelength Tolerance ± 20, ± 10 nm @ 1625 nm
Spectral Width (FWHM) 5 nm (maximum)
Internal Modulation 1 kHz, 2 kHz, CW
Wavelength ID (one, two, or three wavelengths) Compatible with Noyes Optical Power Meters and Light Sources
Output Power Stability < ± 0.25 dB after 15 min
Output Power - 3 dBm

 

VISUAL FAULT LOCATOR
Emitter Type Laser
Safety Class Class II FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Wavelength 650 nm
Output Power (nominal) 0.8 mW into SMF-28

 

GENERAL
Size (in boot) 19 x 11.2 x 4.7 cm (7.5 x 4.4 x 1.9 in)
Weight 0.8 kg (1.7 lb)
Operational Temperature -10 to +50°C, 0 to 95% RH (non-condensing)
Storage Temperature -20 to +60°C, 0 to 95% RH (non-condensing)
Power Rechargeable Li-Ion or AC adapter
Battery Life

(backlight ON in OTDR mode)

12 hours
Display LCD, 320 x 240, 3.5 inch (89 mm), color, transflective
OTDR and OPM Ports Switchable, see web site or contact AFL for available adapter types

 